Products/LoadStor/204.8–716.8 V HV Rack

LoadStor Energy storage

High-voltage Rack-mounted Energy Storage Battery Series

204.8–716.8 V HV Rack

High-voltage rack-mounted storage batteries based on 280 Ah or 314 Ah cells, covering approximately 57–225 kWh.

Cell capacity280 / 314 Ah
Rated charge current100 A
Rated discharge current200 A

LoadStor private-label product. Confirm model, regional supply, equipment combination and delivery scope per project. Prices are hidden by default and quoted after enquiry.

01

PRODUCT OVERVIEW

Understand the product. Know its limits.

The high-voltage rack-mounted storage battery uses a modular series-connected architecture and high-voltage BMS, supports CAN / RS485 communication, and can be selected by system DC bus and energy requirement. The series covers 204.8–716.8 V nominal voltage.

High-voltage DC systems must be designed, protected, insulated, grounded, fire-protected and commissioned by qualified system-integration and electrical personnel. Catalogue life and cycle values are supplier nominal data and should be governed by final contract, test conditions and warranty documents.

Structured models and specifications make project selection clearer

Supports enquiry by load, power and capacity

Original supplier source and page references remain in the internal audit trail

02

TECHNICAL DATA

Technical specifications

Series specifications support initial selection. Final delivery follows the selected model, project design and written quotation.

Cell capacity
280 / 314 Ah
Rated charge current
100 A
Rated discharge current
200 A
Communication
RS485 / CAN
Nominal cycle life
6000 次
Charging temperature
0–55 °C
Discharging temperature
-10–55 °C
Storage temperature
-20–60 °C

Model configuration matrix

Compare capacity, voltage, power and dimensions within this product family. Enquiry and delivery are confirmed by exact model.

ModelDescriptionRated energyRated voltageCell capacityConfigurationCharge cut-off voltageDischarge cut-off voltageWeightDimensionsPrice
XH204.8-280NX-XH204.8-280204.8 V / 57.32 kWh57.32 kWh204.8 V280 Ah16S-4P233.6 V179.2 V520 kg501×820×1040 mmBy enquiryProject confirmed
XH307.2-280NX-XH307.2-280307.2 V / 85.98 kWh85.98 kWh307.2 V280 Ah16S-6P350.4 V268.8 V780 kg501×820×1560 mmBy enquiryProject confirmed
XH409.6-280NX-XH409.6-280409.6 V / 114.64 kWh114.64 kWh409.6 V280 Ah16S-8P467.2 V358.4 V1040 kg501×820×2080 mmBy enquiryProject confirmed
XH512-280NX-XH512-280512 V / 143.3 kWh143.3 kWh512 V280 Ah16S-10P584 V448 V1300 kg501×820×1300(2柜) mmBy enquiryProject confirmed
XH614.4-280NX-XH614.4-280614.4 V / 171.96 kWh171.96 kWh614.4 V280 Ah16S-12P700.8 V537.6 V1560 kg501×820×1560(2柜) mmBy enquiryProject confirmed
XH716.8-280NX-XH716.8-280716.8 V / 200.62 kWh200.62 kWh716.8 V280 Ah16S-14P817.6 V627.2 V1820 kg501×820×1820(2柜) mmBy enquiryProject confirmed
XH204.8-314NX-XH204.8-314204.8 V / 64.28 kWh64.28 kWh204.8 V314 Ah16S-4P233.6 V179.2 V520 kg501×820×1040 mmBy enquiryProject confirmed
XH307.2-314NX-XH307.2-314307.2 V / 96.42 kWh96.42 kWh307.2 V314 Ah16S-6P350.4 V268.8 V780 kg501×820×1560 mmBy enquiryProject confirmed
XH409.6-314NX-XH409.6-314409.6 V / 128.56 kWh128.56 kWh409.6 V314 Ah16S-8P467.2 V358.4 V1040 kg501×820×2080 mmBy enquiryProject confirmed
XH512-314NX-XH512-314512 V / 160.7 kWh160.7 kWh512 V314 Ah16S-10P584 V448 V1300 kg501×820×1300(2柜) mmBy enquiryProject confirmed
XH614.4-314NX-XH614.4-314614.4 V / 192.84 kWh192.84 kWh614.4 V314 Ah16S-12P700.8 V537.6 V1560 kg501×820×1560(2柜) mmBy enquiryProject confirmed
XH716.8-314NX-XH716.8-314716.8 V / 224.98 kWh224.98 kWh716.8 V314 Ah16S-14P817.6 V627.2 V1820 kg501×820×1820(2柜) mmBy enquiryProject confirmed
03

SYSTEM INTEGRATION

Selection, compatibility & delivery

Conditions & compatibility

Electrical parameters, communication protocol and installation environment must be checked for the exact model. System performance, grid interaction and backup capability cannot be inferred from one product sheet alone; final commitments must follow project design, written confirmation and contract.

Installation & commissioning

Selection, transport, installation, protection settings and commissioning must be completed by qualified personnel. High-voltage and commercial systems require project-level electrical, structural, thermal-management and fire-safety review.

04

DOCUMENTATION & SUPPORT

Documents & warranty responsibilities

Warranty & after-sales

Warranty period, applicable regions, spare parts, labour, transport and site-service responsibility are subject to the commercial contract. Written warranty and delivery terms for the selected model should be provided during enquiry; web content does not replace the contract.

Project intake

Define the first system boundary.

A concise brief is enough. Your submission is stored securely and assigned a reference ID for follow-up.

LoadStor / CONSULTATION

Tell us what needs power.

No equipment model or battery size needed. Start with your setting and contact details.

Or contact us directly